Welcome to the eBooster™ Engineering Tool
This tool is provided by eBooster™ (Ecas4 Australia Pty Ltd) for engineering sizing and evaluation of electrochemical systems for active chlorine generation in drinking water and warm water loop applications. It models the electrochemical production of hypochlorous acid (HOCl) from chloride ions naturally present in source water — without the addition of chemical reagents.
System Estimator
Enter water quality parameters or load a water profile, then specify operating conditions to receive a recommended system configuration and operating current for your target chlorine dose.
Advanced Model
Analyse a specific operating point in detail. Set model, current, flow and water chemistry to obtain cell voltage, Faradaic efficiency, ohmic losses, outlet pH and scaling indices.
Please read carefully before proceeding
Model Limitations
This tool is designed for drinking water and warm water loop applications. The following limitations apply:

• Operating temperature range: 5°C to 45°C. Warm water loop mode is fixed at 43°C.
• Faradaic efficiency is estimated using a proprietary model with Arrhenius temperature correction. Results are indicative and may vary from field conditions.
• The Langelier Saturation Index (LSI) and electrode service life (ESL) are engineering estimates only and do not replace laboratory water analysis or on-site verification.
• The polarity inversion interval is a scaling-risk indicator only, not a maintenance schedule.
• Conductivity estimated from ionic composition assumes dilute solution behaviour.
• Results are only valid for the eBooster™ B250, B2k and B10k models.
• The tool does not account for fouling, ageing electrodes, variable feed water quality, or non-ideal hydraulic conditions. For applications outside this scope, or where regulatory compliance is required, contact eBooster directly.
Disclaimer
eBooster™ (Ecas4 Australia Pty Ltd) provides this tool for indicative engineering purposes only. Results produced by this tool do not constitute a binding technical specification, a formal design, a product guarantee, or a representation of system performance under any specific site conditions. The user accepts full responsibility for verifying all results against site-specific conditions, applicable local standards, and regulatory requirements prior to commissioning any installation. eBooster™ and Ecas4 Australia Pty Ltd accept no liability for decisions made, actions taken, or losses incurred on the basis of outputs generated by this tool. For formal engineering design or regulatory submissions, engage a qualified engineer and contact eBooster directly.
Privacy Policy
To access this tool, you are required to register with your name, company, contact number and email address. This information is used solely for the purpose of access control and usage notification. Access is secured via Google Authenticator (TOTP) — your authenticator credentials are stored securely and are not shared with any third party. A summary of your calculation parameters is automatically emailed to Ecas4 Australia upon each successful calculation. Your details are not used for marketing without your consent. By completing the registration form you consent to this use of your information. For privacy enquiries contact info@ebooster.com.au.
Copyright & Intellectual Property
This tool, including its interface, underlying models, algorithms, calculations and all output it generates, is the exclusive intellectual property of eBooster™ and Ecas4 Australia Pty Ltd. Unauthorised reproduction, redistribution, reverse engineering, scraping or commercial use of this tool or its outputs is strictly prohibited. Access is granted for legitimate engineering evaluation purposes only. For licensing or white-label enquiries contact info@ebooster.com.au.
System Estimator — enter water quality and operating conditions to get a system recommendation. Start by loading a water profile or entering parameters manually.
How to use:
1. Enter parameters in 1. Water quality or load a water profile
   ↳ The water quality section will collapse automatically
2. Select the operating mode and related parameters in 2. Operating conditions
3. Review the recommended system in the results column
Application
1. Water quality ►
⚠ No water quality data entered. Load a profile or enter parameters.
2. Operating conditions
Operation mode
3. Recommended system
Fill in the parameters on the left to get a recommendation.
4. Notes & warnings
Enter parameters on the left to see recommendations.
Advanced Model — set current, flow and water parameters to analyse a specific operating point in detail. Alternatively, import data from the Estimator using the button below.
Unit selection
Operating mode
Operational parameters
Current (I)5 A
Flow rate (Q)5.0 L/min
Inlet pH7.2
Initial [Cl⁻]80 mg/L
Total alkalinity100 mg/L
Conductivity (κ)400 μS/cm
Ammonia nitrogen [NH₃-N]0.00 mg/L
Water temperature18 °C
Current efficiency
ηF calculated?Faradaic efficiency — fraction of current that produces Cl₂ rather than O₂. For drinking water: computed from [Cl⁻] and temperature using a calibrated kinetic model (typically 5–20%). For sea water: fixed at 95% (high salinity saturates the kinetic model).
0.0 %
Electrode & circuit parameters
Anodic overpotential (ηa)?Voltage drop at the anode beyond the equilibrium potential, due to kinetic limitations of the electrode reaction. Contributes directly to cell voltage. Default 0.65 V is representative of DSA electrodes at typical operating current densities.0.60 V
Cathodic overpotential (ηc)?Voltage drop at the cathode due to kinetic limitations of H₂ evolution. Contributes directly to cell voltage. Default 0.45 V is representative of stainless steel cathodes.0.30 V
Cable parameters
Total cable length?Length of DC cable between PSU and unit. Longer cables increase ohmic losses at high current.1.0 m
Cable cross-section?Cross-sectional area of the DC cable conductor (copper). Standard IEC sizes. Updates automatically with unit selection — adjust if your installation differs.2.5 mm²
Water quality
Water quality — ionic composition
Enter measured ion concentrations. Conductivity will be automatically calculated from these values.
Cations
Na⁺  λ=50.1 S·cm²/mol
mg/L
K⁺  λ=73.5 S·cm²/mol
mg/L
Ca²⁺  λ=119 S·cm²/mol
mg/L
Mg²⁺  λ=106 S·cm²/mol
mg/L
Fe²⁺  λ=108 S·cm²/mol
mg/L
Mn²⁺  λ=107 S·cm²/mol
mg/L
Anions
Cl⁻  λ=76.3 S·cm²/mol
mg/L
HCO₃⁻  λ=44.5 S·cm²/mol
mg/L
SO₄²⁻  λ=160 S·cm²/mol
mg/L
NO₃⁻  λ=71.5 S·cm²/mol
mg/L
F⁻  λ=55.4 S·cm²/mol
mg/L
Enter ion concentrations to check charge balance.
Loading...
Estimated voltage and power
Cell voltage
0.00
V
Power consumption
0.00
W
Gas void fraction (anode / cathode)?Fraction of interelectrode gap volume occupied by gas bubbles (O₂ at anode, H₂ at cathode). Bubbles reduce the effective electrolyte conductivity.: — / —
Bulk κ at T: — μS/cm
Effective κ (Bruggeman correction): — μS/cm
pKa(HOCl) at T: —
Cell ohmic drop: — V
Cable ohmic drop: — V
Active chlorine production
Actual active chlorine
— mg/L
Active chlorine dose
— g/h
Energy yield
— g/kWh
HOCl at outlet pH
— %
Theoretical Cl₂ (Faraday)
— mg/L
Estimated Cl⁻ consumption
— mg/L
Current efficiency ηF
— %
Chlorine demand & chloramines
No ammonia nitrogen — no chloramine chlorine demand.
pH variation
Inlet pH
7.2
→
Outlet pH
7.20
ΔpH  
+0.000
Operational limits
Applied current & electrode service life (ESL)
I = — A  |  Recommended: ≤ — A  |  Maximum: — A  
ESL estimated: —
Chloride availability
Available Cl⁻: — mg/L  |  Required: — mg/L  
Local electrode conditions
pH at the electrode surface estimated via Graetz-Lévêque diffusion layer model. These are local values — bulk outlet pH is shown above. Note: bulk pH change is typically very small due to bicarbonate buffering; larger shifts measured on collected samples may reflect CO₂ degassing during sampling rather than a true bulk pH change.
Diffusion layer δ
— μm
Local pH — cathode
—
Local pH — anode
—
Langelier Saturation Index (LSI) — requires Ca²⁺ and alkalinity
Saturation pHⓘ
—
LSI — bulk outletⓘ
—
LSI — cathode surfaceⓘ
—
−3 (corrosive)0 (balanced)+3 (scaling)
>